<1.5 amol ATP per well or <1.5 zmol Firefly luciferase per well.">
Direct Line
Centro XS³ LB 960 high-sensitivity microplate luminometer
Centro XS³ LB 960 high-sensitivity microplate luminometer
Centro XS³ LB 960 microplate luminometer open
Centro XS³ LB 960 microplate luminometer injectors
Centro XS³ LB 960 microplate luminometer automation
Microplate Readers

Centro XS³ LB 960

High Sensitivity Microplate Luminometer

The microplate luminometer Centro XS³ LB 960 is a high-sensitivity instrument able to detect <1.5 amol ATP per well or <1.5 zmol Firefly luciferase per well.

The Centro XS³ LB 960 meets all currently known requirements for a robust and sensitive microplate luminometer. The reader supports all basic luminescence technologies including

  • Flash-type Luminescence, e.g reporter gene assays
  • Glow-type Luminescence

The selected detector and the proprietary design of the optical system guarantee lowest background and negligible crosstalk. It is the instrument of choice for reporter gene assays and ATP determination when highest sensitivity is required.

For routine applications that do not need the maximum sensitivity the standard Centro LB 960 could be the best option.

Built-in Reagent Injectors

  • Up to 3 reagent injectors
  • Superior accuracy and precision (JET Injection technology)
  • Excellent mixing performance
  • Variable injections speeds and "friendly" material enable even injection of live cells
  • Reagent bottles can be kept in ice or at elevated temperatures

 

Waste Pump

  • Excess fluids from priming and washing procedures are safely discarded via an automatic waste pump

Highest sensitivity

  • <1.5 amol ATP per well
  • <1.5 zmol Firefly luciferase per well

 

Small footprint

  • Requires minimum space
  • Reagent injectors housed within housing
  • Short injector tubing and low dead volume

Standard Centro XS³ Configurations

46970-10
Centro XS³ Basic, enhanced sensitivity, 96/384 well, upgradeable with injectors, incl. MikroWin Lite software

46970-50
Centro XS³ Basic Reporter Gene, enhanced sensitivity, 96/384 well, 2 reagent injectors, incl. MikroWin Lite software

Options for Centro XS³

48532
Injector assembly with 3 injectors (#3, #2, #1), 10 - 100 μL each

48533
Injector assembly with 2 injectors (#3, #2), 10 - 100 μL each

48775
Injector assembly with 1 injector (#3), 10 - 100 μL

37772-21
Injector 1 pre-position 3, 10 - 100 μL

37772-22
Injector 2 pre-position 2, 10 - 100 μL